Operating instructions (Cont,)

Selecting a Relative Humidity Setting:

All of the settings on your dehumidifier are electronioally
controlled.

50% maintains a 50% Relative Humidity level
60% maintains a 60% Relative Humidity level
70% maintains a 70% Relative Humidity level

80% maintains a 80% Relative Humidity level

"CONTINUOUS" will dehumidify "non-stop"

To select a Relative Humidity setting,
(Continuous, 50% 60%, 70%, B0%)

1. Depress the "DRY" keypad until the required setting is

selected. Each depression of the keypad will change
the relative humidity setting, Identified by the .

illuminated window adjacent to your selection made. (If
existing relative humidity conditions in your room

register "lower" than the relative humidity level
selected, No dehumidlfytng will take place (flashing

^green window). The fan will operate but the

compressor will remain in an oft cycle, until the relative

humidity level is lowered accordingly (below RH level

of room).

Selecting a Fan Speed Mode:

1. To select a fan speed, each depression of the

"Fan" keypad will alternate between the "High" &
"Low" fan speed settings, identified by the
illuminated window adjacent to your selection.

Heat mode:

The Heat mode provides a feature that will allow you the

option to setting temperatures in either "Celsius" or
"Faren height".

NOTE: This must be accomplished before you pre-select

the HEAT mode option

It is not possible to access existing ambient room

conditions during HEAT mode.

2. Depress the

<S>

keypad, allowing you to alternate

between the ’C^F RH settings adjacent to the

LED display

3. When the window adjacent to the ‘C illuminates,

the LED will display temperatures in "Celsius".

4. When the window adjacent to the *F illuminates,

the LED will display temperatures in
"Farenheighr. The illuminated RH window

automatically defaults to the 'C (Celsius) scale

HEAT MODE:

To select "Heat", depress the "mode” key pad. Each
depression of the key pad will alternate №rough each of
the optional modes. (DRY, HEAT, FAN) When the window

adjacent to the " Heat" mode illuminates, the selection is
complete.

Temperature:
To select/adjust "temperature" depress either of the

(S>/<5>

key pads.

The

<S>

keypad increases temperature settings, (as

outlined below)
The

<S>

keypad decreases temperature settings, (as

outlined below)

(Celsius scale 1* increments) Adjustable temperature

range 10‘C-32'C)

(Farenheight scale 2* increments) Adjustable temperature
range 48‘F-92’F)

The temperature appearing In the LED display is the
temperature at which heater will cycle.
Both heater and fan will stop, when the ambient room

temperature reaches the set temperature, displayed in th*

led

window

Fan Speed!
Each depression of the "Fan" keypad will alternate

between the "High" &,"Low" fan speed settings,
identified by the illuminated window adjacent to your
selection.

• High Fan: will produce 1150 watts of Heating output.
• Low Fan will produce 950 watts of Heating output

Follow these steps:

1. Depress the MODE keypad to select either DRY

or FAN, identified by the illuminated window
adjacent to the selection.

10