Before you call for service trouble shooting – Danby DBD5L User Manual

Page 20

Advertising
background image

Problem

Possible Causes What To Do

1)The beverage

dispenser is not

cooling

2) Beer or beverage

is not being

dispensed

3)The dispenser

temperatre display

is not illuminated

4) Excessive foam,

spilling, or spraying

occurs

5) The dispenser is

1) No power supply

1a) Low voltage

1b) Blown fuse

2) The mini keg or

container is empty.

2a) The DISPENSING or

AIR-CONNECT TUBE is

pinched.

2b)The air pressure switch

is in the AIR OFF position.

2c) Air is leaking.

3) No power

3a) The power switch

remains in the OFF (O)

position.

4) First glass

4a) The mini keg is not

cold enough, or has been

shaken.

4b) The DISPENSING

TUBE or AIR-CONNECT

TUBE is leaking, or the

ADAPTOR is not prop-

erly sealed.

4c) Dispensing tap is not

open enough

5) The air pressure is

1) Make sure the dispenser is plugged into a 3 prong

outlet

1a) Make sure the dispenser is plugged into a proper

120V outlet

1b) Change fuse. It is recommended that a qualified

electrician change the fuse on the dispenser

2) Change the keg or container.

2a) Make sure the TUBES are not kinked when

connected. If necessary, turn the keg in the dispenser

to even out the TUBES.

2b) Switch the air pressure to the AIR ON position

2c) Make sure there is an air-tight seal between the

keg and the RISING PIPE. Also, make sure the

CONNECTORS and TUBES are properly attached and

secured. If necessary, change the TUBES.

3) Make sure the dispenser is plugged into a 3 prong

outlet.
3a) Push the power switch to the ON (

l

) position.

4) The first glass from a keg can have too much foam.

This is normal.

4a) Always pre-chill the mini keg before tapping, and

store keg where there is little or no movement for at

least 24 hours before using to allow for chilling and

rest.

4b) Make sure the TUBES are properly connected. If

necessary, change the TUBES. Make sure the

ADAPTER is securely fastened to the mini keg. If

necessary, re-connect.

4c) Pull the tap handle completely down to ensure the

tap opens up.

5) The air pressure switch is turned to the ON

position.This is normal. If not in use, turn to the OFF

position.

BEFORE YOU CALL FOR SERVICE

TROUBLE SHOOTING

making a humming

noise

turned off

20

Advertising