6. SPECIFICATIONS

ALPHA C-25 Manual V2.1.doc

Page 19

6. SPECIFICATIONS

AC Line Input:

120 volts ± 5%, 50/60Hz, 13 amperes or

230 volts ± 5%, 50/60Hz, 6 amperes
(selectable on rear of unit) NOTE: Unit will
operate ± 10% but with lower max amp
ratings at -10%.

Constant Current
Mode:

Capacity

Accuracy

Approx. 37 volt limit non-adjustable. 0-7 to 8
amps at 37 volts.
< ± 3% from charge initiation to completion

Constant Potential
Mode

Setting

Selectable 14.3/28.5 volts; 25 ampere limit.
Adjustable.

Accuracy

< ± 0.2 volts

Timer

Setting

Adjustable from 0 to 999.9 minutes

Units

Selectable on front of timer from 0.1 to 999.9
minutes

Accuracy

< ± 0.1%

Digital
Meter Accuracy:

Voltmeter

< ± 0.3 volts

Ammeter

< ± 0.3 amperes

Cooling:

Fan cooled

Housing:

Aluminum chassis

Outer Dimensions: Height

14 in. (356 mm)

Depth

15 in. (381 mm)

Width

5 3/4 in. (146 mm)

AC Line Cord:

AWG 14 3 wire grounded 6 ft long with 120
volt 15 ampere plug. User required to change
to 230 volt plug if needed.

DC Discharge
Cable:

Two 4 ft long, terminated in ring terminals
(Aircraft Battery Connector Optional)

Weight:

Net weight 45 lbs (20.4 kg).

Fuses:

AC line fuse

20A/250V, type MDA 1 1/4 x 1/4

DC line fuses

Two 35A/32V, type AGC 1 1/4 x 1/4

Modes:

1) Constant Current mode without voltage
limit

2) Constant Potential mode for 12 volt and
24 volt batteries.