August 30, 2002 Manual Version 1.0

3.12

module) and a group of eight channels for that module. One module may have up to 16 channels. The
PREVIOUS PAGE softkey will appear above the NEXT PAGE softkey only after the NEXT PAGE
softkey is used to select a group of eight other than those shown on the first page. Use the Up/Down
arrow keys to move the cursor (highlight) to a channel whose settings are to be changed. In the figure
above, channel 5 on die protection module 1 is selected. Press the upper right softkey (CHANNEL
SETTINGS). This will take you to the Die Protection Settings screen for channel 1, module 5, shown in
Figure 3.10.





















Figure 3.10 Die Protection Channel Settings Screen

Note that the Die Protection Channel Settings screen is channel specific, i.e., since channel 5 of die
protection module 1 was selected when the CHANNEL SETTINGS softkey was pressed in Figure 3.1,
the Die Protection Configuration screen that appears will allow you to settings for this particular
channel. The upper right softkey is now labeled SUPPLY ACCESS CODE. Pressing this softkey will
cause a popup table to appear listing user names as shown in Figure 3.11.

When the user name is selected in the screen shown in figure 3.11, the user name code entry box will
appear as shown in Figure 3.12. Use the number keys on the Operator Terminal keypad to input the
code associated with the user name and press the ENTER key.








Stroke

Mode

Drive

Speed
Stroke
Speed

SPM

SPM

0
0

Order

Counter

SYSTEM STATUS

Counter OFF

Die
Protection

SUPPLY
ACCESS
CODE

CHANNEL
DIAGS

NEXT
CHANNEL

0

0

OK

TOP

EXIT

0

90

270

180

Die Prot. Channel Configuration

Module: 1 Channel: 5

Channel Type:

Description:

Input Type:

Stop Type:

Bypassed:

Delay Time:

Delay Strokes:

Window On:

Window Off:

Cyclic

Left Front Stripper

Normally OFF

Top Stop

No

0 msecs

0 Strokes

154

0

213

0

Help

Sets the type of Logic

to apply to the

channel

Cyclic - Norm. OFF

Used to monitor events that occur

once per machine cycle. The input

must be ON somewhere in the timing

window AND OFF somewhere in the

timing window.

PREVIOUS
CHANNEL

DECREMENT
ON ANGLE

INCREMENT
ON ANGLE

DECREMENT
OFF ANGLE

INCREMENT
OFF ANGLE

SoftKey

Press the
SUPPLY
ACCESS CODE