The main configuration menu is used to configure – LINK Systems OmniLink II Press Automation Control User Manual

Page 53

Advertising
background image

August 30, 2002 Manual Version 1.0

4.4

Pressing the NEXT PAGE softkey causes the second page of the Device Configuration menu to be
displayed, as shown in Figure 4.3.





















Figure 4.3 Device Configuration Menu, Second Page.


The OmniLink II Press Automation Control provides for up to 5 Die Protection and Process Monitoring
Modules, each with either 8 or 16 inputs. Before toggling a Die Protection and Process Monitoring
Module to a “Used” setting of Yes, you must assign each module a module number. This is done by
opening the door of each module and setting a rotary switch in the module you wish to designate as
module 1 to the number 1. For each module used, set a different successive number on the rotary switch
that indicates module number. When you have finished, an LED number display in the front door of
each module indicates module number when power is on. Once you have assigned a module number to
each die protection module to be used with the system, toggle to Yes for the “Used” setting for each
module number used.

Section 4.2 The Main Configuration Menu

The Main Configuration Menu is used to configure:

1. Settings based on the characteristics of the press upon which the OmniLink is installed. Brake

Monitor Stop Time Limits, Clutch Engagement Time Limit, and stroke length are examples of
settings that depend on the individual press.

2. Settings for Encoder Offset, Auto Top Stop Compensation, Top of Stroke Angle

3. Choices of what you wish to show on areas of the Operator Terminal Display in certain areas

reserved for user customization.

Stroke

Mode

Drive

Speed
Stroke
Speed

SPM

SPM

0
0

Order

Counter

SYSTEM STATUS

Counter OFF

0

0

OK

TOP

Device
Config

TOGGLE
USED

UPDATE
PROGRAM

EXIT

PREVIOUS
PAGE

Device Configuration

Device

Used Status

Die Protection Module 1

Die Protection Module 2

Die Protection Module 3

Die Protection Module 4

Die Protection Module 5

Yes

No

No

No

No

Hardware Detected :

Hardware Version :

Bootcode Version :

Software Version :

Avail. Version :