Connecting the transformer, Step 1, Step 2 – Mighty Mule FM352 User Manual

Page 28: Important information about low voltage wire

Advertising
background image

24

M i g h t y M u l e 3 5 2

Connecting the Transformer

GTO indoor

Transformer

(surge protector

not supplied)

Run 1000' (max.) of low

voltage wire to control

board from transformer

(wire not included)

.

PVC conduit (not included) to protect

wire from lawn mowers and weed eaters.

Master Opener

Step 1

Select the 120 Volt electrical outlet into which you will plug the transformer. Lay the low voltage wire in a
trench following a path from the selected electrical outlet to the control box. Wires coming up from the
ground should be run through PVC conduit to protect them from lawn mowers, weed eaters, and grazing
animals. Be sure to bury the wire laid in the trench.

Step 2

Bring enough wire up through the PVC

conduit to allow for gate movement

from open to closed position. See

example right.

IMPORTANT INFORMATION ABOUT LOW VOLTAGE WIRE

The only wire acceptable for use with GTO products is 16 gauge multi-stranded, low voltage,

PVC sheathed wire. This particular gauge enables the transformer to provide an adequate

charge through the control board to the battery at distances up to 1000 ft.

DO NOT

use telephone wire or solid core wire. Unlike multi-stranded wire, these types of wire

are inadequate for use with your gate opener system. Telephone wire and solid core wire do

not deliver enough voltage for your gate opener to function and will cause the system to go

into a condition known as "low voltage lockout."

NEVER

splice wires together. Splicing permits corrosion and seriously degrades the wire's

ability to carry an adequate current.

IMPORTANT: Never connect the transformer and a solar panel to the opener control board at the same

time. It will damage the control board.

If you are using SOLAR PANEL(S) to charge the opener battery, skip this section and go to "Connecting

Solar Panel(s)" section on page 26.

Advertising