Pinnacle Systems NSD 3580 User Manual

Page 2

Advertising
background image

www.pinnaclesystems.com

2

www.pinnaclesystems.com

www.pinnaclesystems.com

Page 2 / 2

Suitable for monitoring of emergency-stop circuits

Yes

Suitable for monitoring of optoelectronic protection equipment

Yes

Suitable for monitoring of position switches

Yes

Output circuit

Enabling paths

3

Signaling paths

1

Contact material

Ag-alloy, gold-plated

Max. thermal current Ith, enabling paths

6 A

Max. thermal current Ith, signaling paths

2 A

Max. total current I2 of all current path

25 A²

Application category AC-15 (NO)

Ue 230V, Ie 3A

Application category DC-13 (NO)

Ue 24V, Ie 5A

Short-circuit protection (NO), max. fuse insert

6 A class gG fuse, fuse integral < 100 A²s

Mechanical life

107 switching cycles

Control circuit

Nominal output voltage DC

22.5 V

Input current (safety circuit / reset circuit)

25 mA

max. peak current (safety circuit / reset circuit)

100 mA

Response time tA1

250 ms

Response time tA2

250 ms

Min. switch-on time

60 ms

Recovery time tW

120 ms

Release time tR

20 ms

Synchronous time tS

1.5 s

Permissable test pulse time tTP

0.8 ms

max. resistivity, per channel

≤ (5 + (1,176 x UB / UN - 1) x 100) Ω

Type of switch function of the inputs

Normally open contact

Evaluation inputs

2-channel

Supply circuit

Nominal voltage UN

DC 24 V

Rated consumption DC

1.6 W

Operating voltage min.

22.4 V

Operating voltage max.

26.4 V

Dimensions

Depth

114 mm

Width

22.5 mm

Height

96.5 mm

Advertising