Rear panel description – Cloud Electronics 46-120TMedia User Manual

Page 12

Advertising
background image

46-120 Installation and User Guide V1.2

12

Rear panel description

4 6

8

22

9

6

7

5

20

21

11

1

2

3

3 3

3 3

3

1

1

1

1

1

12

7

10 10 10 10

16

13

17 19

18

14

15

1.

LINE 1 to LINE 6

– 6 pairs of RCA (phono) sockets for connection of music sources. Inputs are stereo, summed

internally to mono. See page 14.

2.

LINE 1/MEDIA – selects whether Music Source 1 is fed from LINE 1 inputs or the internal digital media player. This

push-button switch is only fitted to models 46-120

MEDIA

and 46-120T

MEDIA

.

3.

GAIN – preset trim control for each line input, providing ±10 dB of gain adjustment for input level matching. See page

21.

4.

MIC 1/TEL – balanced microphone input on 3-pin 3.5 mm-pitch screw-terminal connector. See page page 15.

This input should be used in conjunction with the

ACCESS CONTACTS connector [7] for paging; it can also be

configured internally for use with a telephone system, See page 22.

5.

MIC 2 – balanced input for a second microphone; 3-pin 3.5 mm-pitch screw-terminal connector.

6.

GAIN – preset mic gain controls for MIC 1 and MIC 2, gain range 10 to 60 dB. See page 22.

7.

HF and LF – preset mic EQ controls. See page 22.

8.

ACCESS CONTACTS – 6-pin 3.5 mm-pitch screw-terminal connector for per-zone paging access by contact

closure. See page 16.

9.

MUSIC CONTROL – 12-pin 5 mm-pitch screw terminal connector for connection of RL-1/RSL-6 remote control

plates. See page 17.

10.

MUSIC CONTROL LEV & SRC – two push-button switches per zone which determine whether front panel music

source (

SRC) and level (LEV) controls will remain active when remote control plates are connected. See page 17.

11.

ZONE 1 FACILITY PORT – 8-pin RJ45 socket, for connection of LM-2 remote active modules, or as an auxiliary

input. See page 15.

12.

AUX OUT – unbalanced line level outputs for Zone 1 and Zone 2 at 0 dBu. See page 20.

13.

SPEAKER OUTPUTS – outputs for each zone on 8-pin 5 mm-pitch screw-terminal connector. See page 19.

These will be low impedance (min. load 4 ohms) on the 46-120 and 46-120

MEDIA

models, and 70 V-line on the 46-120T

and 46-120T

MEDIA

models (as standard). If one or more CXL-46T transformers have been retrofitted to a 46-120 or

46-120

MEDIA

, they may be either 100 V or 70 V-line. A checkbox area is provided below the connector for the installer

to indicate the configuration of each zone output.

14.

MOH/UTILITY OUTPUT – an auxiliary output whose source can be set by internal jumpers. The output is available

as both unbalanced line level (0 dBu) and a galvanically-isolated output suitable for driving 600 ohm inputs, as found on
telephone system MOH (Music On Hold) inputs. See page 19.

15.

MOH/UTILITY MIC 1 & MUSIC LEVEL – two pre-set controls, adjusting the level of the Mic 1 input and chosen

music source respectively at the Utility Output. See page 23.