23

system. This permits announcements to be made from some
(or any) internal telephone extensions in a building. Not
all telephone systems are suitable for this application, and
the system documentation should be consulted in detail to
ensure compatibility.
Internal jumpers J17A, J17B and J17C need to be moved
for this application. See page 30 for further information
regarding the internal jumpers.

This inserts a transformer

in series with the input connector to provide full electrical
isolation from the telephone system. Note that the mic input

sensitivity is decreased by 10 dB when the transformer is
enabled, and this results in the mic gain control operating
over the range 0 dB to 40 dB.
The audio (or “paging”) output of the phone system should
be connected to the

MIC 1/TEL input in the normal way. The

telephone input is optimised for connection to a 600 ohm
output; this should suit the majority of telephone systems.
Note that the front panel

MIC 1 LEVEL controls [3] are

still operational.

Zone and MOH/Utility outputs

In normal operation, the music level in each zone will be
set by the front panel

MUSIC LEVEL control, or by a

corresponding control on a remote plate or module (or other
control system). The music level at the Utility/MOH output
will be set by the rear panel

MOH/UTILITY MUSIC

LEVEL preset control.

EQ

The various zones in a building often have different acoustic
properties, and may also have different models of loudspeaker
installed. The 46-120 is fitted with per-zone HF and LF EQ
adjustments for the music signal ([5] on page 11) to enable
the audio frequency response to be best matched to each
zone’s acoustics. The controls should be adjusted by listening;
up to 10 dB of cut or boost at 10 kHz (HF) and 50 Hz (LF) is
available. Note that these EQ adjustments do not affect the
frequency response of the microphone signal.
After the EQ has been adjusted during system commissioning,
the EQ presets may be made inaccessible by fitting the
security cover (one supplied with each Mixer Amplifier). See
page 29 for fitting instructions.

MOH/Utility output settings

The

MOH/UTILITY output of the 46-120 can be used

for various purposes: a common application is to drive
loudspeakers (using additional power amplifiers) in secondary

areas such as corridors, lobbies or toilets, where there is no
necessity to make frequent alterations to the music source
or level.

Eight source options are available for the signal at the MOH/
Utility output, selected by internal jumper J16. This jumper is
in the form of a 2x8-way header, with a link being positioned
on one pair of pins only. The options are:
• The output is always fed with the music signal connected

to any one of LINE 1 to LINE 6. When in use with a
telephone system as an MOH source, it is generally more
desirable for the music source to remain constant; these
options are available for this purpose.

• The output always follows the music source selection

made for Zone 1 (either on the front panel or via remote
control). The

MUSIC LEVEL control for Zone 1 does

not affect the level at the MOH/Utility output. This option
is the factory default setting.

• The output is always fed with the output of the media

player. The rear panel LINE 1/MEDIA switch setting is not
relevant, and the media player may be used simultaneously

as Music Source 1, or not, as wished. This option is only
operative on models 46-120

MEDIA

and 46-120T

MEDIA

.

See page 30 for locations and settings of PCB jumpers.

The signal at the

MOH/UTILITY output may be any

required mix of the selected music signal and the microphone
signal connected at the

MIC 1/TEL input, and is set using the

rear panel presets

MOH/UTILITY MIC 1 LEVEL control

and

MUSIC LEVEL (see [15] at page 12). Each signal is

effectively ‘off’ with the preset control in its fully anticlockwise
position. Note that the signal at this output is NOT altered by
any front panel

MUSIC LEVEL or MIC LEVEL controls,

or any front panel MUSIC EQ preset adjustments.

The

MOH/UTILITY MIC 1 LEVEL control

should be turned fully down if the output is to be
used for MOH with a telephone system, otherwise
paging announcements will be heard by telephone
callers.

If Zone 1 is selected as the MOH/Utility source (the factory
default setting), and Line 6 Priority is enabled (see page 24),
the MOH/Utility output will switch to Line 6 along with
Zone 1 output if the input becomes active.

High-pass filters

When the 46-120 is used to drive 70/100 V-line loudspeaker

systems via internally-fitted CXL-46T transformers (as in the
46-120T and 46-120T

MEDIA

), there is a risk of transformer

saturation at high levels and low frequencies. To prevent
this, each of the 46-120’s four channels is provided with a
switchable 65 Hz high-pass filter. These should be enabled for
any channels being used to drive 70/100 V-line systems.
The filters are enabled by moving internal PCB jumpers J3
(Zone 1), J4 (Zone 2), J8 (Zone 3) and/or J9 (Zone 4). See
page 30 for locations of PCB jumpers.
In models 46-120T and 46-120T

MEDIA

, the jumpers are set at

the factory in the ‘ON’ position (filters enabled) for all zones.