Specifications

Audio Inputs:

·

Two XLR connectors, a female and a male, allow either unbalanced monaural or unbal-
anced stereo audio input.

·

Four (4) AES/EBU digital audio (program in) switched 110 ohm female XLR

·

Configurable sample rate of 44.1KHz or 48KHz

·

AES/EBU inputs are failsafe bypassed to outputs in the event of power failure.

Audio Outputs:

·

Four (4) AES/EBU digital audio (program out) switched 110 ohm male

Audio Frequency Response

·

0 to 20 KHz, -3 dB

Controls:

LAN Interface: TCP/IP Ethernet

·

Standard: One (1) 10/100 BASE-T RJ45

·

Assignable IP addressing either fixed or DHCP (unit ships fixed at (192.168.001.002)

GPO’s (General Purpose Outputs):

·

Four (4) [One (1) per channel] Form C relays with Normally Open (NO) and Common
(C) outputs rated .5A @200VDC

·

10-pin detachable terminal strip

GPI’s (General Purpose Inputs)

. Master switch GPI

·

Four independent GPI contacts, one for each AES section

Front Panel

·

Green power status lamp

Physical Attributes

·

19.0” W x 12.0” D x 1.75” H (1RU EIA rackmount)

Power Requirements

·

Input

90 -240 VAC @ .5 amps (25 Watts)

·

Standard IEC power cord

Weight

·

7 lbs