5 Configuration

Pos: 31 /806-IHSE/Konfiguration/Übertragungsparameter/472-xx @ 6\mod_1304494757555_6.doc @ 50488 @ 2

5.1

Transmission Parameters

In default configuration, the device adapts dynamically to monitor
resolution and image content. This configuration is suitable for almost all
conditions and should only be modified if image quality is not fully
satisfactory.


Pos: 32 /806-IHSE/Konfiguration/Geräteeinstellungen/472-xx @ 6\mod_1305032093070_6.doc @ 51594 @ 3

5.1.1

Device Settings

Both CPU unit and CON unit have four DIP switches that are used to set
the KVM Extender to the respective operation mode, depending from the
respective device.

DIP settings have to be performed both CPU and CON unit into the same
positions.
Only set DIP switches if the extender is not connected to power supply.

DIP

Function

Switch
Position

Switch down

Switch up

Not used

Single Link mode
(default in combination with Single Link devices)

Dual Link mode
(default in combination with Dual Link devices)

Switch mode
(default in combination with models with integrated switching
function)

Standard mode, no HDCP possible (default in combination
with USB-HID / analog audio / serial devices)

HDCP mode, no USB-HID / analog audio / seriell possible
(default with USB 2.0 devices without analog audio / serial)

In HDCP mode, the transmission of USB-HID and analog audio signals is
blocked.