9530/8530 Manual Version 4.8


Within the System Mode menu set the mode to Single Shot mode.

Within the Trigger menu:

o Select the Triggered mode.
o Set the trigger threshold level to ~50% of the incoming signal.
o Select either rising or falling edge for the unit to trigger on.

Pressing the Run/Stop key will arm the unit. Once the unit is armed it will generate a T

0

pulse for

every external trigger received. Pressing the Run/Stop button again will disarm the unit. This mode
corresponds to the normal external trigger mode found on most other pulse generators.

Generate a Burst of Pulses on Every Trigger Input

To generate a burst of pulses on every trigger input set the following parameters:

Within the System Mode menu:

o Set the mode to Burst.
o Set the number of pulses that is desired for each input signal.
o Press the Page button and set the T

0

pulse to the period desired between pulses.

Within the Trigger menu:

o Select the Triggered mode.
o Set the trigger threshold level to ~50% of the incoming signal.
o Select either rising or falling edge for the unit to trigger on.

Pressing the Run/Stop button will arm the unit. Once the unit is armed it will generate a set of
pulses for every external trigger received. The units’ timer is reset at the end of a burst and will
generate another set of pulses upon receiving a new trigger. Triggers that occur in the middle of a
burst will be ignored. Pressing the Run/Stop key again will disarm the unit.

Start a Continuous Stream of Pulses Using the External Trigger

The external trigger may be used to cause the unit to start generating pulses by setting:

Within the System Mode menu select Continuous mode.

Within the Trigger menu:

o Select the Triggered mode.
o Set the trigger threshold level to ~50% of the incoming signal.
o Select either rising or falling edge for the unit to trigger on.

Pressing the Run/Stop button will arm the unit. Once the unit is armed it will start generating pulses
after an external trigger is received. Triggers that occur after the initial trigger will be ignored.
Pressing the Run/Stop key again will disarm the unit.