Vinpower Digital HDDShark User Manual

Page 17

Advertising
background image

14

4)

Read Error Skip*
This setting will allow for the change to the number of times the system will skip
ahead when it encounters a reading error, while reading the source hard drive.

By default, the system does not skip any reading error, which would result in an
immediate job failure if any read error occurred during the duplication process.

*Enable this setting will not fix any discovered error(s); it will merely skip it and
read the remaining data of the source hard drive.

5)

Write Error Skip*
This setting will allow for the change to the number of times the system will skip
ahead when it encounters a writing error, while writing to the target hard drive.

By default, the system does not skip any writing error, which would result in an
immediate failure for such target hard drive if any write error occurred during the
duplication process.

*Enable this setting will not fix any discovered error(s); it will merely skip it and
continue write to the next data block of the target hard drive.

6)

Partition Layout
This setting will allow user to adjust various partition layout options for the target
hard drive during the duplication process under “SMART”/”Partition” mode.

There are two options for this setting:

Auto Ratio: The system will automatically adjust the partition layout under the
same ratio as the source hard drive.








As It: The system will set the partition layout exactly same as the source hard
drive regardless the capacity differences.









Partition Layout
Auto Ratio

Partition Layout
As It

Advertising