LowFlow Mark 708SH Series Short Pattern 1/4 User Manual

Page 3

Advertising
background image

-3-

Clean all parts with an approved non-residue-form-

6.

ing solvent. Remove encrusted material with a very

fine Crocus or aluminum oxide cloth. However, do

not use these abrasives on the seating surface or

the trim surface (the portion of the plug that enters

the seat bore.) The machining tolerances on these

surfaces are so closely controlled that you might

change the valves flow characteristic.

Inspect all parts and replace and worn or damaged

7.

parts. It is always advisable to replace seals and

gaskets. DO NOT attempt to resurface seating sur-

faces of the plug or seat. Seats and plugs are only

sold in factory-matched sets.

Valve Reassembly

Soft seated valves: insert soft seat into the seat

1.

cavity, install the seat cap and tighten.

Lubricate the seat threads with a lubricant such as

2.

NO-LOK and thread the seat into the body. Torque

to values shown.

Valve Size

Seat Torque

ft. - lbs.

in. - lbs.

3/4”

26

310

1/2”

20

240

Guided trim: coat the guide portion of the plug

3.

with MOLYKOTE G-Rapid Spray lubricant or an

equivalent light lubricant suitable for your service.

Assemble plug to stem.

Insert the stem into the bonnet. Set the gasket

4.

around the boss on the bonnet. Carefully assemble

the bonnet to the body and allow the plug to center

into the seat. Push down on the stem to be sure

that the plug has fully engaged the seat. Hand-

tighten the body bolts.

Valve Size

Gasket Material

Quantity Required

All

Teflon

1

1/2” & 3/4”

Grafoil

2

Remove and replace the packing as described in

5.

“Packing Replacement”.

While holding the plug firmly in position in the

6.

seat, secure the body to the bonnet with the bolts.

Torque bolts evenly to the values shown.

Torque Values (in. - lbs.)

Material

Bolt Diameter

Limitation

5/16”

3/8”

Gr. BD*

125

200

650 deg. (also SAE GR. 8)

Gr. B7

125

200

1000 deg. F

Gr. B6

125

200

900 deg. F (410 SST)

* Standard Bolting

Reassemble the two stem nuts and indicator all the

7.

way onto the stem threads.

If the actuator is reverse acting (ATO), apply ap-

8.

proximately 6 psig air pressure to the actuator. If

MOTOR VALVE, position to full open.

Insert hex bolts through the yoke and into the bon-

9.

net flange. Next, place the packing adaptor (7)

into the packing box, and then the packing gland

(9) over the top of the packing adaptor. Secure

the packing gland with the gland nuts (11). Thread

the stem into the actuator stem. Hold the actuator

stem with a wrench to prevent it from turning. In-

stall the nuts onto yoke hex bolts and tighten. (You

can press down on the actuator to compress the

springs and bring the yoke into contact with the

bonnet flange.) The actuator spring preload must

be adjusted; refer to “Actuator Spring Preload Ad-

justment”. For Motor Valve see “Motor Valve Seat

Spring Pre-Load”.

Actuator Spring Preload Adjustment

The two stem nuts should be loosened and thread-

1.

ed down on the stem and then locked together.

Lock the valve stem into the stem connector, then

thread the stem connector in the actuator stem.

A regulated air supply must be provided to the

2.

actuator. Connect the air to the lower case for re-

verse acting or to the upper case for direct action

actuators.

Standard actuators have ranges of either 3-15 psig

3.

or 6-30 psig. The range is stamped on the valve

nameplate. These instructions will assume that the

range is 3-15. If yours differs, substitute the appro-

priate pressure where these instructions refer to 3

or 15 psig.

4a. Direct Acting Actuator (ATC): Slowly increase the

air pressure up to 15 psig while observing the stem

for movement. Downward travel should stop ex-

actly at 15 psig. If the downward travel stops before

15 psig is reached, thread the stem connector into

the actuator stem by wrenching on the locked stem

nuts and keeping the actuator stem from turning to

avoid twisting the diaphragm and/or toppling the

springs. If the downward travel continues after 15

psig is reached, thread the stem connector out of

the actuator stem.

4b. Reverse Acting Actuator (ATO): The valve plug

is closed against upward fluid thrust by actuator

spring force. Total compression placed on the ac-

tuator spring must be sufficient to provide preload

plug force required to close the valve. If preload

adjustment is made with no pressure in valve body,

then, when the control valve is placed in opera-

tion, additional compression must be placed on the

spring to provide valve closure force. With proper

adjustment, valve will close tightly and will not be-

gin to open until the preload pressure is exceeded.

Slowly increase the air pressure up to 3 psig while

observing the stem for movement. Adjust spring

preload until valve just starts to open when 3 psig

air pressure is supplied to the actuator diaphragm.

Advertising