Pressure hose, Safety requirements, Cleaning and maintenance – Powerplus POW67935 PRESSURE PUMP 1000W 20L EN User Manual

Page 6: Cleaning, 8 cleaning and maintenance

Advertising
background image

POW67935

EN

Copyright © 2014 VARO

P a g e

| 6

www.varo.com

7.1

Pressure hose

The pressure hose is used for conveying the water from the pump to the water consumption
point (e.g. tap, etc.). In order to minimize the friction loss caused by the water pressure, we
recommend that you use a pressure hose with a minimum diameter of 3/4".
 When the garden pump is working, the water outlet (e.g. tap or water sprinkling outlet)

must be open so as to discharge the air from the hose. If the water outlet is closed, the
pump may be damaged due to overheating of the pump after working for more than 5
minutes.

 Freezing of the pump or placing it in a frosty space in the winter must be avoided.
 Sand and stones in the water taken in can rapidly wear the pump and reduce its effective

capacity. It is therefore necessary to install a filter.

 This water pump is not suitable for long-term operation, e.g. in industrial or mining

enterprises or for a water recycling system.

7.2

Safety requirements

 The power supply must comply with the specifications displayed on the product. Refer to

the instructions of your local energy supplier if necessary for connecting conditions. If the
pump or the power cable do not comply, do not connect the pump!

 Never carry the pump by the cable and never pull the pump by the cable out of the pond.

Never remove the plug and never shorten the cable. If you do, you will invalidate your
guarantee. Keep the connection (plug and socket) dry.

 The pump is not suitable for use in swimming pools and lakes or other situations where

persons could come into physical contact with the water, and must therefore not be used
for this purpose.

 Always disconnect the pump from the power supply when cleaning it or carrying out

maintenance to the pond. This pump is suitable for pumping water with a minimum
temperature of 4 °C and a maximum temperature of 35 °C. The pump must not run dry, as
this will cause irreparable damage.

 Clean the chambers from time to time, rinsing them with clean water, to ensure they are

not clogged with dirt.

8 CLEANING AND MAINTENANCE

Attention !Before performing any work on the equipment, pull the power
plug.

8.1

Cleaning

Under normal conditions, the water pump is free of maintenance. However, the pump should
not be placed in the open air during rain, in a humid place, or dirty or frozen environment.
 Freezing, idling or blocking by impurities should be avoided.
 Always disconnect the power supply before maintenance of the pump.
 If the power cable is damaged, it must be replaced by professional personnel. Damage

caused by short circuiting is not included in scope of the guarantee.

 If trouble with the pump is experienced, guaranteed repairs must be carried out by an

authorized maintenance center.

Never use solvents such as petrol, alcohol, ammonia water, etc. These
solvents may damage the plastic parts.

Advertising