Technical Specification

Description Test

Signal

Limit

K factor K 2T

NTC-7 comp

<1%

Pulse X bar K rating

100 +/- 1%




Frequency Response
(MultiBurst)

FCC Multi-burst
0.5 MHz
1.25 MHz
2 MHz
3 MHz
3.58 MHz
4.1 MHz


0dB +/- 0.2 dB
0dB +/- 0.2 dB
0dB +/- 0.2 dB
0dB +/- 0.2 dB
0dB +/- 0.3 dB
0dB +/- 0.3 dB

Differential Gain

NTC-7 comp

<2%

Differential Phase

NTC-7 comp

<1 Degree

Non-Linearity NTC-7

comp

<5%

Jitter

<5nS

Weighted Luminance Noise

Luminance Ramp

<60 dB

Weighted Luminance Noise

Flat Grey Field

<63 dB

Chrominance PM Noise

Flat Red Field

<55 dB

B.1.4

Performance Figures

Table B.5 HD Analogue Output Specification

Parameter Value

for

Y, R, G, B

Value for
Pb, Pr

Condition Notes

Amplitude

700 mV

± 2%

700 mV

± 2%

100% color bar

DC offset

± 10 mV

± 10 mV

Black field

Bandwidth

DC to 10 MHz

± 0.2 dB

10 MHz to 20 MHz

± 1 dB

20 MHz to 30 MHz
+1 dB/-2.5 dB

DC to 10 MHz

±

0.2 dB
10 MHz to 15 MHz

±

1 dB

Sweep

Group delay

DC to 30 MHz < 50nS

DC to 30 MHz < 50nS

Noise

DC to 30 MHz < -50 dB

DC to 30 MHz < -
50 dB

100% ramp

Out-of-band noise

30 MHz to 100 MHz
< -50 dB

15 MHz to 100 MHz
< -50 dB

Sweep

Linearity

< 5%

< 5%

5 step