26

[Display power (On/Off) sync]

(Depending on model)
(This function is only supported by the Signage box)

This is a function to control the power of the Display connected to the HDMI OUT to be synchronized with the power

of the Signage box.

When the power of the Signage box is changed from Off to On, it turns on the Display and tries to switch the input

to the Signage box screen.

When the power of the Signage box is changed from On to Off, it turns off the Display.

[On/Off]: Enable/Disable this function

NOTE

It is necessary to enable the CEC function on the Display

[Crestron]

(Depending on model)

This function enables synchronization with applications provided by Crestron.

Server: This menu sets the server’s IP address for the network connection with the server (equipment provided by

Crestron).

Port (1024~65535): This menu sets the port for the network connection with the server. The default port number is

41794.

IP ID (3-254): This menu sets a unique ID for synchronizing with the application.

The connection status of the server type shall be indicated by pictures and phrases. (Disconnected, Connecting,

Connected)

Type: You can select the server type you want to connect to (Off, Control System, Virtual Control, Fusion)

CONNECT: If you press the button once, a set tries to connect to the server and the button phrase is changed into

DISCONNECT. In this case, the upper items are immutable. To disconnect and change upper items, pressing the button

again is needed.

Information for connecting with the server

- Type: Control System

- Server: Enter the IP information of the server

- Port: Enter the Port information for the server

- IP ID: A unique ID that distinguishes crestron equipment from server

- Type: Virtual Control

- Room ID: A unique ID that distinguishes room from server. If the IP ID is the same, but the Room ID is different,

the server recognizes it as a different crestron equipment.

- Server, Port, IP ID are the same as Control System’s.