CHAPTER 3: CONNECTING TO THE NETWORK

Page 18

BRIM-E6 USER’S GUIDE

2. If the Internal Termination switch is in the On position, connect the

thin-net segment directly to the BNC port as shown in
Figure 4-3.

3. If the Internal Termination switch is in the Off position:

a.

Attach a BNC tee-connector to the BNC port on the module.

b.

Attach the thin-net segment to one of the female connectors on
the tee-connector.

Note: You must terminate each segment attached to the tee-connector. If
you do not attach a segment to one of the female connections on the
tee-connector, then a terminator must be placed on that connection.

c.

Attach another thin-coax segment or a terminator to the other
female connector on the tee-connector.

Figure 3-3. The EPIM-C

Attach thin-net segment directly to BNC
connector when internal termination
switch is set to on ( ).

When internal termination switch
is set to off ( ):

Connect BNC tee-connector to port.

Attach a terminator or terminated
thin-net segment to one female
connector of tee-connector.

Connect a terminated thin-net
segment to other female connector
of tee-connector.