background image

16–14

Statistics Programs

Program Lines:

(In RPN mode)

Description

  ª 

  º





 

 ª

 -+.

 H

%



  !

Returns to the calling routine.

Checksum and length: 1981 42

Flags Used:

None.

Remarks:

The accuracy of this program is dependent on the display setting. For inputs in the
area between ±3 standard deviations, a display of four or more significant figures
is adequate for most applications.

At full precision, the input limit becomes ±5 standard deviations. Computation time
is significantly less with a lower number of displayed digits.

In routine Q, the constant 0.5 may be replaced by 2 and



.

You do not need to key in the inverse routine (in routines I and T) if you are not
interested in the inverse capability.

Program Instructions:

1.

Key in the program routines; press

‡

when done.

2.

Press

X

S.

3.

After the prompt for M, key in the population mean and press

g

. (If the

mean is zero, just press

g

.)

4.

After the prompt for S, key in the population standard deviation and press

g

. (If the standard deviation is 1, just press

g

.)

5.

To

calculate

X

given Q(X), skip to step 9 of these instructions.