4.6 Packet Commands

C156-E205-01EN

4-51

4.6.4.4 Power Condition page

Table 4.60 Power Condition Page

Bit

Byte

7

6

5

4

3

2

1

0

0

PS (1)

0

Page Code (1Ah)

1

Page Length (0Ah)

2

Reserved

3

Reserved

Idle

Standby

4-7

Idle Condition Timer (in 100-ms unit)

8-11

Standby Condition Timer (in 100-ms unit)

The values specified for the Idle bit and Idle Condition Timer are ignored. It
always operates in accordance with the default timer value in the ODD.

When the Standby bit is 1, specify the time after the device enters idle mode until
it enters standby mode.

The Idle Condition Timer value and the Standby Condition Timer value are
specified with a value in 100-ms units.

If the value specified for the Standby Condition Timer is not a multiple of 600
(258h), the ODD automatically rounds down the fractions to a value in 60-second
units.

Power Condition Page can be saved.

Table 4.61 Power Condition Page Variable

Bit

Byte

7

6

5

4

3

2

1

0

2

0

3

0

0

1

4-7

0

8-11

ffffffffh