4. It is recommended that the burner gas pressure be checked at this time by the local gas company
or an authorized service agent. Refer to “Check Burner Pressure” in Chapter 4 of this manual for
the proper procedure. The accompanying tables list the burner gas pressures for the various gas
types that can be used with this equipment.
Gas
Pressure
Natural Lacq
(G20) under 20 mbar
7 mbar
Natural Gronique*
(G25) under 25 mbar
12 mbar
Propane
(G31) under 37 mbar
22,2 mbar
CE Standard for
Burner Gas Pressure
* Belgian G25 = 7,0 mbar
Gas
Pressure
Natural
3.5" WC
0.87 kPa
8.718 mbar
Propane
8.25" WC
2.05 kPa
20.55 mbar
Non-CE Standard for
Burner Gas Pressure
2.5
Converting to Another Gas Type
DANGER
Your cooker is configured at the factory for a specific type of gas. If you desire to
switch from one type of gas to another, specific gas-conversion components must
be installed.
Switching to a different type of gas without installing the proper conversion
components may result in fire or explosion! NEVER attach your cooker to a gas
supply for which it is not configured.
Conversion of this appliance from one type of gas to another should only be
performed by qualified, licensed, and/or authorized installation or service personnel,
as defined in Section 1.7 of this manual.
G20 or G25 (Natural) to G31 Gas:
G31 (Propane) to G20 or G25 Gas:
Orifice: 810-1970 (2 required)
Orifice: 810-0916 (2 required)
Ignitor Kit: 826-1715 (2 required)
Ignitor Kit: 826-1714 (2 required)
Conversion Rating Label 802-2144
Conversion Rating Label 802-2144
CE Gas Conversion Components
Natural Gas to LP (Propane) Gas:
LP (Propane) Gas to Natural Gas:
Orifice: 810-0917 (2 required)
Orifice: 810-0916 (2 required)
Ignitor Kit: 826-1715 (2 required)
Ignitor Kit: 826-1714 (2 required)
Regulator: 807-1848 (1 required)
Regulator: 807-1847 (1 required)
Conversion Rating Label 802-2144
Conversion Rating Label 802-2144
Non-CE Gas Conversion Components