5 lan input/output, 6 pilot plug – Furuno FA-100 User Manual

Page 24

Advertising
background image

18

3.5 LAN

Input/Output

The FA-100 supports Ethernet based on LAN. Its protocol is 10BASE-T and the
transmission rate is 10 Mbps. To connect the FA-100 with other equipment (such as
a PC), use a LAN cable category 4 or higher with shield (SDT). Connect it to the
PC with an RJ-45 connector, and connect to the FA-100 with a D-sub 9 pin
connector, to avoid noise leakage. To use a commercial LAN cable, remove one
connector and solder a D-sub 9 pin connector, supplied in the installation materials.

TD+

TD-

RD+

RD-

GND

F.GND

LAN (10B-T)

FA-100

>1>

>2>

>3>

>4>

>8>

>9>

3 RD+

6 RD-

1 TD+

2 TD-

Twisted pair cable

RJ-45 (Category 4 and higher, SDT)


3.6 Pilot

Plug

Use the twisted cable TTYCS-4 between the junction box and the pilot plug. The
cable between the PC and the pilot plug should be prepared by the ship’s pilot.

Junction box
Terminal board

TD A

TD B

RD-A

RD-B

SHIELD

TB1

>1>

>2>

>3>

>4>

>5>

>6>

>7>

>8>

>9>

J1

37 TD8-A

38 TD8-B

39 GND ISO

40 RD8-A

41 RD8-B

42 GND ISO

Pilot plug

TTYCS-4

3mm Crimp-on lug

206486-1
(AMP)

PC