FUJITSU MHW2060AC User Manual

Page 130

Advertising
background image

Interface

Command data structure

Indicates the command received when an error occurs.

Error data structure

Indicates the status register when an error occurs.

Total number of drive errors

Indicates total number of errors registered in the error log.

Check sum

Two's complementary for the lowest-order 1 byte that is obtained by adding 1 byte
after another for as many as 511 bytes beginning from the top of the structure.

Status

Bits 0 to 3: Indicates the drive status when received error commands according to

the following table.

Bits 4 to 7: Vendor unique

Status Meaning

0 Unclear

status

1 Sleep

status

2 Standby

status

3

Active status (BSY bit = 0)

4

Off-line data collection being executed

5 to F

Reserved

Table 5.17 Data format of SMART Comprehensive Error Log

Byte

First sector

Next sector

00h

SMART Error Logging 01h

Reserved

01h

Index Pointer Latest Error Data Structure.

Reserved

02h...5Bh 1

st

Error Log Data Structure

Data Structure 5n + 1

5Ch...B5h 2

nd

Error Log Data Structure

Data Structure 5n + 2

B6h...10Fh 3

rd

Error Log Data Structure

Data Structure 5n + 3

110h...169h 4

th

Error Log Data Structure

Data Structure 5n + 4

16Ah...1C3h 5

th

Error Log Data Structure

Data Structure 5n + 5

1C4h...1C5h

Total Error Count

Reserved

1C6h...1FEh Reserved

Reserved

1FFh Checksum

Checksum

5-54

C141-E258

Advertising