5.3 Host Commands

SMART self-test

The host computer can issue the SMART Execute Off-line Immediate sub-
command (FR Register = D4h) and cause the device to execute a self-test. When
the self-test is completed, the device saves the SMART self-test log to the disk
medium.

The host computer can issue the SMART Read Log Sector sub-command (FR
Register = D5h, SN Register = 06h, SC register = 01h) and can read the SMART
self-test log.

Table 5.18 SMART self-test log data format

Byte Item

00, 01

Self-test log data structure

02

Self-test log 1

Self-test number (SN Register Value)

03

Self-test execution status

04, 05

Life time. Total power-on time [hours]

06

Self-test error No.

07 to 0A

Error LBA

0B to 19

Vendor unique

1A to 1F9

Self-test log 2 to 21

(Each log data format is the same as that in
byte 02 to 19.)

1FA, 1FB

Vendor unique

1FC Self-test

index

1FD, 1FE

Reserved

1FF Check

sum

Self-test number

Indicates the type of self-test executed.

Self-test execution status

Same as byte 16Bh of the attribute value.

Self-test index

If this is "00h", it indicates the status where the self-test has never been executed.

Check sum

Two's complementary for the lowest-order 1 byte that is obtained by adding 1 byte
after another for as many as 511 bytes from the top.