Marathon monitors inc – Marathon Computer AACC 2000 User Manual

Page 78

Advertising
background image

Marathon Monitors Inc.

AACC 2000 Carbon Nov. 1, 1997

78

2. To invert a PID output, the Val. H can be set below the Val.L

Name

Description

Values Meaning

For ‘

id

id’ = ‘dC.OP’, ‘dc.rE’, or ‘dc.OP’ use this parameter table:

Func

Function

nonE

Function disabled

HEAt

Heating output

COOL

Cooling output

PV

Retransmission of PV

wSP

Retransmission of setpoint

Err

Retransmission of error signal

OP

Retransmission of OP power

VAL.L

% PID, or Retrans’n Value,
giving minimum output

VAL.H

% PID, or Retrans’n Value,
giving maximum output

unit

voLt = Volts, mA = milliamps

Out.L

Minimum electrical output

Out.H

Maximum electrical output

For ‘

id

id’ = ‘LoG.i’ (i.e logic input) use the

LA

LA Conf’ list on Page 6-11.

2A

2A/b

b/C

C

Module 2 configuration

As per module 1 configuration, but excluding the ‘

SSr.1’, ‘SSr.2’ functions.

id

Identity of module installed.
As per module 2 plus:

tPSU

Transmitter power
supply

Pot.i

Potentiometer input

Continued on next page

VAL.L

Out.H

Out.L

VAL.H

Electrical
Output

%PID, or Retransmission Value