MRV Communications TERESCOPE TS800/155 User Manual
Page 30
M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l
20
Figure 2.4 shows an unacceptable TereScope link location because of interference by
passing vehicles. Notice that the TereScopes are mounted far from the rooftop
edges and not high enough above the ground.
Figure 2.4: Unacceptable Mounting
Mounting Environment & Stability
1. When deciding the mounting location, you should look on the
rooftop for vibration sources such as compressors, elevators,
motors, and try to avoid them.
2. Photograph the mounting location so as to select the best
mounting option.
Figure 2.5 shows mounting locations on a rooftop in descending
order of preference. Location 1 is the best; location 7 is the worst.
Figure 2.5: Mounting Locations in Order of Preference