Flue outlet, 24 icos, Installation – IDEAL INDUSTRIES ICOS HE18 User Manual

Page 24: 30 flue terminal position

Advertising
background image

24

icos -

Installation & Servicing

INSTALLATION

FLUE OUTLET

rf8394-1

690mm

Fixed

300mm

min

30 FLUE TERMINAL POSITION

rf8393-1

300mm

min

300mm

min

625mm

Fixed

Flat roof - with structure

The terminal should be positioned so that products of
combustion can safely disperse at all times.

Pluming may occur at the termination so, where
possible, terminal positions where this could cause
a nuisance should be avoided.

Minimum dimensions are shown below

Terminal Position

Minimum Dimension

Directly below an opening,

air brick, windows, etc.

300 mm

Below plastic / painted gutters

300 mm

Painted surface

300 mm

Below eaves or balcony

500 mm

rf8392