FAULT FINDING

F

AUL

T FINDING F

AUL

T FINDING F

AUL

T FINDING F

AUL

T FINDING F

AUL

T FINDING

70 L.....F.......

(FLAME ERROR)

Check the ignition electrode and associated harness for:

continuity, visual condition, position

(Refer to Frame 56).

Are these functioning correctly ?

Check gas valve

wiring for

continuity

YES

Check the detection electrode and

associated harness for:

continuity, visual condition, position

(Refer to Frame 57).

Replace as necessary.

If the boiler reset button is

pressed does the boiler ignite for

a short time then extinguish?

Is 200V DC supply available

at the gas valve ?

NO

YES

YES

Is gas pressure available at

the boiler inlet ?

Replace PCB

Check gas supply

and rectify fault

Replace ignition electrode and associated

harness as necessary

NO

Replace gas valve

YES

NO

NO

71 L.....E......

or

H.....E......

(BOARD ERROR)

Internal fault within the PCB

Replace PCB

Note. Due to the wave form of the rectified voltage the reading will vary, depending on the type of meter used to

measure the value (some may measure the possible peak voltage of 339V). In general terms, a reading greater
than 150V indicates that the correct voltage is supplied to the gas valve. As an alternative to a multimeter a
mains checking device may be used. E.g. an electrical screwdriver or a mains tester.

Check spark generator and associated

harness for continuity and visual condition.

Refer to Frame 58. Are these functioning

correctly?

Replace

spark generator

YES

NO

Press and hold reset button for 2

seconds. Does boiler operate

correctly?

Turn boiler off and wait for 5

seconds.Turn boiler on.

Does boiler operate correctly?

NO

NO

YES

OK

YES

OK

Check syphon

and condensate

drain pipework

for blockage

Check for an excess voltage between neutral

and earth. Is the value below 50V?

LE ONLY: Check continuity of OH thermostat.

Is this correct?

HE ONLY: Check earth wire is connected to

detection lead. Is this correct?

Check all earths for continuity

YES

YES

YES

YES

Check earth connection to the boiler. If value is still in

excess of 50V consult a Qualified Electrician to check the

household electrical supply and circuitry

Correct wiring or replace thermostat

Correct wiring or replace detection lead

Correct connections

NO

NO

NO

NO