Service procedures – Sanyo CL4232 User Manual

Page 56

Advertising
background image

– 56 –

SM830078

12. SERVICE PROCEDURES

C. Check compressor motor magnetic contactor.

F. Check float switch. (XS Type only)

• Refer to “2-3 Drain Pump Control”

D. Check indoor unit P.C.B.

1036_X_S

• Check voltage between
terminals L1 and L2 at
terminal plate.

• Check P.C.B. Ass’y.

No voltage appears.

P.C.B. Ass’y is defective.

E. Check outdoor unit P.C.B.

(CL3632 Type)

• Check coil resistance of
compressor motor magnetic
contactor. (52C)

1035_X_S

0628_X_S

• Check voltage between
terminals No.2 and No.4 at
terminal plate.

• Check P.C.B. Ass’y.

No voltage appears.

P.C.B. Ass’y is defective.

0629_X_S

Is drainage prevented from
flowing ?

• Check drain hose.

YES

• Check float switch (FS).

NO (Wait for 20 minutes.)

Advertising