MIXER TEST RUN

1. Check for proper assembly, adjustment, and lubrication. Check to see that there is adequate oil in the oil

bath. Check to be sure all bolts and set screws are tight and the drive belts are at the proper tension. Review

OPERATING SAFETY PRECAUTIONS in the SAFETY section and the LUBRICATION section before

operating the mixer.

2. Be sure all shields are properly in place.

3. Check for and remove any foreign objects in the mixer hopper and discharge opening.

4. Check to see that drain plugs are installed and that the discharge door is closed.

5. Be sure no one is inside the mixer.

6. Test run the mixer.

a. Make sure mixer is empty, then start the mixer.

b. Run for at least five minutes.

c. Raise and lower the door several times.

d. Turn off mixer and lock out power.

e. Check the mixer drive components to be sure they are not abnormally hot. Refer to

Inspection and Adjustment section for proper alignment and tension settings.

If any of these items are not running as indicated, immediately repair or contact your service representative. Always

refer to OPERATING SAFETY PRECAUTIONS in the SAFETY section before operating or servicing the mixer.

MIXER SETUP

READ AND FOLLOW THESE INSTRUCTIONS WHEN SETTING UP THE MIXER.

To avoid personal injury: The hopper floor may be slippery and the augers or reel can spin

unexpectedly when stepped on. Use caution when stepping or standing inside the unit; put a

protective cover over the auger knives.

MODEL

SHEAR BOLT SIZE

3136

1/4” X 2” GRADE 5

3142

1/4” X 2” GRADE 5

3150

1/4” X 2” GRADE 5

3160

1/4” X 2” GRADE 5

3170

5/16” X 2” GRADE 5

3195

5/16” X 2” GRADE 5

DRIVELINE SHEAR BOLTS
3136, 3142, 3150, 3160, 3170 & 3195 ONLY

The driveline has a shear bolt assembly for overload protection. This shear bolt type overload protection needs very

little maintenance. If the motor free spins during operation, the shear bolt has broken. Replace the sheared bolt with

a new one of the same diameter, length and grade. Any bolt of different specifications than listed below will prevent

the shear bolt assembly from operating properly and can cause damage to the mixer.