PROBLEM: EXCESSIVE CHAIN NOISE

MISALIGNED SPROCKETS

Check sprockets for worn edges of teeth. Use a straight edge to

verify the alignment of the sprockets.

WORN SPROCKET AND OR CHAIN

Inspect sprockets and chains. Replace if excessively worn.

CAUSE

SOLUTION

PROBLEM: SEAL LEAKING ON UPPER AUGER

CAUSE

SOLUTION

PROBLEM: SEAL LEAKING ON INPUT SHAFT

OIL BATH IS OVERFILLED

The oil level in the sealed drive compartment should be maintained

at the “oil level” plug on the drive compartment housing. This

allows the oil to be thrown onto all the other chains inside the

drive compartment.

SEAL IS DAMAGED

Replace Seal

CAUSE

SOLUTION

PROBLEM: FEED IS SEPARATING AS IT DISCHARGES FROM THE MIXER DOOR

CAUSE

SOLUTION

TROUBLE SHOOTING

PROBLEM: MOTOR RUNS, BUT REEL AND AUGERS DO NOT TURN

CAUSE

SOLUTION

SHEAR BOLT ON PTO DRIVELINE HAS SHEARED

BELTS ARE SLIPPING

BROKEN CHAIN

Replace with the same grade and size shear bolt. Do not use any

bolt other than the grade specified in the MIXER SETUP,

DRIVELINE SHEAR BOLTS section. If problem persists, call your

local dealer.

Adjust or replace belts ad outlined in the INSPECTION AND

ADJUSTS section. If problem persists, call your authorized Kuhn

Knight service dealer.

Make sure that mixer is not overloaded. Replace broken chain. A

spliced chain will not be as strong as a new chain and may break

in another place. Be sure to inspect bearings, bearing mounts,

and shafts for any damage caused by excessive pressure.

BOLTS MAY HAVE WORKED LOOSE ON SEAL RETAINER

Tighten or replace bolts

SEAL IS DAMAGED

Replace Seal

DOOR IS OPEN LESS THAN HALF WAY

Hay mixed in the load will separate from the grain if the discharge

door is not open at least half way. Additional flow control plates

may be required.