OPERATION

B-4

LN-25™ PIPE

POWER-UP SEQUENCE

All of the LEDʼs will briefly illuminate during power-up.
If the gun trigger is activated during power up, the
feeder will not operate until the gun trigger is released.

WIRE FEED SPEED/AMPERAGE DISPLAY

Idle
The left display shows the preset wire feed speed.
The right display shows OCV. The wire feed speed
LED is lit.

Welding
The value in the left display will be either amps or
actual wire feed speed, depending upon the selection
chosen in the set-up menu. The corresponding LED
below the display will light. Note that actual WFS may
not match preset WFS, if welding at low voltages with
high wire feed speeds. The right display shows the arc
voltage. If the wire feeder is connected for electrode
negative welding, then the voltage display shows a
minus sign.

After Welding
The display continues to hold the value of the amper-
age
or WFS and arc voltage for five seconds after
welding stops. The amperage or WFS and voltage
displays flash.

SET-UP MENU

Preparation for WFS Calibration:

• Place the CV/CC switch in CV.

• Set the display to the desired wire feed speed

(example: 400 inches per minute)

• Measure the actual wire feed speed (example: 405

inches per minute)

• Place the WFS knob in the 12 oʼclock position.

Preparation for Amperage Calibration:

Connect the feeder to a power source and grid.
Adjust the power source and grid to the desired
amperage. (example: 220 Amps)

Record the amperage display on the wire feeder.
(example: 210 amps)

To enter the set-up menu, use paper clip to press the
small button located on the case front.