5-14 Programmer’s Manual

M S I I N F O

The MSIINFO data structure contains scanner configuration
information about MSI bar codes. To read these values,
applications call scnGetMSIInfo; to set these values, they call
scnSetMSIInfo.

typedef struct _MSIInfo

{

unsigned char uchEnable;

unsigned char uchLength1;

unsigned char uchLength2;

unsigned char uchCheckDigits;

unsigned char uchXmitCheckDigit;

unsigned char uchChkDgtAlgorithm;

} MSIINFO;

Field Description

uchEnable

Enable/disable the ability to scan MSI bar

codes.

Default: SCN_DISABLE

uchLength1

uchLength2

Specifies lengths for MSI bar codes. You

can specify one or two lengths, a range of

lengths, or that any length is valid. Enter

values as follows:
Option

uchLength1 uchLength2

1 Length

Value

0

2 Lengths

High Value Low Value

Range

Min. Value Max. Value

Any length 0

0

Default: 6 (uchLength1) and 55

(uchLength2).