Environmental specifications, Connector pin assignments – Nortel Networks Circuit Card User Manual
Page 539
NT8D02 and NTDK16 Digital Line cards
Page 539 of 906
Circuit Card
Description and Installation
Environmental specifications
Table 175 shows the environmental specifications of the card.
Connector pin assignments
Table 176 shows the I/O pin designations at the backplane connector, which
is arranged as an 80-row by 2-column array of pins. Normally, these pin
positions are cabled to 50-pin connectors at the I/O panel in the rear of each
module for connection with 25-pair cables to the MDF.
The information in Table 176 is provided as a reference and diagnostic aid at
the backplane, since the cabling arrangement can vary at the I/O panel. See
Communication Server 1000M and Meridian 1: Large System Installation
and Configuration (553-3021-210) for cable pinout information for the I/O
panel.
Table 175
Digital line card – environmental specifications
Parameter
Specifications
Operating temperature
0° to +60° C (+32 to +140° F), ambient
Operating humidity
5 to 95% RH (non-condensing)
Storage temperature
–40° to +70° C (–40° to +158° F)
Table 176
NT8D02 Digital Line card – backplane pinouts (Part 1 of 2)
Backplane
Pinout*
Lead
Designations
Backplane
Pinout*
Lead
Designations
12A
Line 0, Ring
12B
Line 0, Tip
13A
Line 1, Ring
13B
Line 1, Tip
14A
Line 2, Ring
14B
Line 2, Tip
15A
Line 3, Ring
15B
Line 3, Tip
*
These pinouts apply to both the NT8D37 and NT8D11 backplanes