NT8D41AA Serial Data Interface Paddle Board

553-3001-211 Standard 3.00 August 2005

Configuring the SDI paddle board

Configuring the SDI paddle board consists of setting these option switches for
each serial port:

Port address

Baud rate

DTE/DCE/Fiber mode

The SDI paddle board has seven option switches, SW 2–8. Figure 159 on

page 676

identifies the location of option switches on the SDI paddle board.

Instructions for setting these switches are in the section that follows.

Once the board has been installed, the system software must be configured to
recognize it. Instructions for doing this are found in “Software service
changes” on

page 677

.

8

CTS

Clear to send (Note 1)

Clear to send

Note 1: In DTE mode the signals CD, DSR, and CTS are tied to +12 volts to signify that the port
on the SDI paddle board is always ready to transmit and receive data.

Note 2: In DCE mode the signals DTR and RTS are tied to +12 volts to signify that the port on
the SDI paddle board is always ready to transmit and receive data.

Table 211
Connectors J1 and J2 pin assignments (Part 2 of 2)

Pin #

Signal

Purpose in DTE mode

Purpose in DCE mode