Reference and power sources, 5 external references, 5 v power source – National Instruments NI USB-6009 User Manual
Page 25: Specifications, Analog input, Are listed in the
© National Instruments Corporation
25
NI USB-6008/6009 User Guide and Specifications
Reference and Power Sources
The NI USB-6008/6009 creates an external reference and supplies a power
source. All voltages are relative to COM unless otherwise noted.
+2.5 External References
The NI USB-6008/6009 creates a high-purity reference voltage supply for
the ADC using a multi-state regulator, amplifier, and filter circuit. The
resulting +2.5 V reference voltage can be used as a signal for self test.
+5 V Power Source
The NI USB-6008/6009 supplies a 5 V, 200 mA output. This source can be
used to power external components.
Note
While the device is in USB suspend, the output is disabled.
Specifications
The following specifications are typical at 25 °C, unless otherwise noted.
Analog Input
Converter type........................................ Successive approximation
Analog inputs ......................................... 8 single-ended, 4 differential,
software selectable
Input resolution
NI USB-6008 .................................. 12 bits differential,
11 bits single-ended
NI USB-6009 .................................. 14 bits differential,
13 bits single-ended
Max sampling rate (aggregate)
1
NI USB-6008 .................................. 10 kS/s
NI USB-6009 .................................. 48 kS/s
AI FIFO.................................................. 512 bytes
Timing resolution ................................... 41.67 ns (24 MHz timebase)
1
System dependent.