Shock and Vibration

To meet these specifications, you must panel mount the EtherCAT system
and affix ferrules to the ends of the power terminal wires.

Operating shock (IEC 60068-2-27) ........30 g, 11 ms half sine,

50 g, 3 ms half sine,
18 shocks at 6 orientations

Operating vibration,
random (IEC 60068-2-64) ......................5 g

rms

, 10 to 500 Hz

Operating vibration,
sinusoidal (IEC 60068-2-6) ....................5 g, 10 to 500 Hz

Cabling

Table 2 shows the standard Ethernet cable wiring connections.

Table 2. Ethernet Cable Wiring Connections

Pin

Connector 1

Connector 2

1

white/orange

white/orange

2

orange

orange

3

white/green

white/green

4

blue

blue

5

white/blue

white/blue

6

green

green

7

white/brown

white/brown

8

brown

brown