TANDBERG 3G Gateway

Data port Command Interface User Guide

Trunk CircuitIdentificationCode: The Circuit Identification Code is a unique identifier for

a data time slot in a cable (trunk). In this case the CIC acts as base address and can be
defined for each SS7 trunk and sets the first time-slot number of the respective SS7 trunk.

Route DPC: Unique identifier indicating the destination signaling point of a trunk.

Route Priority: Priority level of the route to the destination signaling point. Fail-over

signaling paths will be followed according to this priority.

Route LinkSet: Indicates the link to the destination signaling point according to the above

mentioned priority setting.

For more details on the sub-commands please read the chapter about SS7 in the 3G Gateway
User Manual.


Example of SS7 feedback:
*c xConfiguration SS7 OPC: 0

*c xConfiguration SS7 NetworkIndicator: National0

*c xConfiguration SS7 Law: ALaw

*c xConfiguration SS7 LinkSet 1 Mode: Off

*c xConfiguration SS7 LinkSet 1 DPC: 0

*c xConfiguration SS7 LinkSet 1 Link 1 Mode: Off

*c xConfiguration SS7 LinkSet 1 Link 1 Trunk: 0

*c xConfiguration SS7 LinkSet 1 Link 1 Timeslot: 0

*c xConfiguration SS7 LinkSet 1 Link 1 SLC: 0

*c xConfiguration SS7 LinkSet 1 Link 2 Mode: Off

*c xConfiguration SS7 LinkSet 1 Link 2 Trunk: 0

*c xConfiguration SS7 LinkSet 1 Link 2 Timeslot: 0

*c xConfiguration SS7 LinkSet 1 Link 2 SLC: 0

*c xConfiguration SS7 LinkSet 2 Mode: Off

*c xConfiguration SS7 LinkSet 2 DPC: 0

*c xConfiguration SS7 LinkSet 2 Link 1 Mode: Off

*c xConfiguration SS7 LinkSet 2 Link 1 Trunk: 0

*c xConfiguration SS7 LinkSet 2 Link 1 Timeslot: 0

*c xConfiguration SS7 LinkSet 2 Link 1 SLC: 0

*c xConfiguration SS7 LinkSet 2 Link 2 Mode: Off

*c xConfiguration SS7 LinkSet 2 Link 2 Trunk: 0

*c xConfiguration SS7 LinkSet 2 Link 2 Timeslot: 0

*c xConfiguration SS7 LinkSet 2 Link 2 SLC: 0