3 secondary controller for pgm1/2/3/4, 4 control type, Limitations – EVS MulticamLSM Version 10.03 - July 2010 Configuration Manual User Manual

Page 83: Pgm1/2/3/4, Econdary, Ontroller for, Ontrol

Advertising
background image

Issue
10.03.C

EVS

Multicam – Version 10.03 – Configuration Manual

EVS Broadcast Equipment SA – July 2010

76

3.17.3 S

ECONDARY

C

ONTROLLER FOR

PGM1/2/3/4

Possible values: list of protocols defined on page 7.1. Default: ---------- --

Available only if the main controller for that channel is an EVS remote.

Special Control Settings p.7.3
Main RS422 Second. RS422
PGM5:[F1]---------- -- [F5]---------- --




[Menu]Quit [Clr+F_]Dft [F9]PgUp [F0]PgDn

Multicam is now capable of operating in LSM Base Config with 5 play channels
assigned. On this Protocol assignment page, the user can define the protocols and

ports to manage this channel.

The LSM Remote by itself cannot control PGM5.

3.17.4 C

ONTROL

T

YPE

Special Control Settings p.7.4
Control type OSD Display
PGM1:[F1]Parallel [F5] Main
PGM2:[F2]Exclusive
PGM3:[F3]Exclusive
PGM4:[F4]Exclusive

[Menu]Quit [Clr+F_]Dft [F9]PgUp [F0]PgDn

Possible Values: Parallel, Exclusive (default)

This setting allows channels to either be controlled in ‘Exclusive’ control (same as

allowed in the past with 2

n d

Control Mode) or in Parallel Mode.

In Parallel mode, the user can define which device will manage the OSD display
characters (i.e. the main or the secondary controller).

Limitations

Some configurations (*) lead to the following message to warn the users of the
limitations of the selected configuration:

“Warning: your parallel selection is not fully operational”