Velleman HAA85BL User Manual

Page 12

Advertising
background image

HAA85BL

v2

15/11/2013

VELLEMAN

12

Exit programming mode. All above data stored and
ready for use

NOTE: * Entering single user command code 8901 is not necessary if the keypad was already in single

user mode.
Cancel a wrong entry with

or wait 10 seconds and retry.

3.

Operating the keypad – Taking the data programmed above and other default features as reference

a.

To command output 1, enter one of the user codes in group 1 and validate with

.

Output 1 activates for 1 second

Output 1 activates for 1 second

Output 1 activates for 1 second

b.

To command output 2, enter one of the user codes in group 2 and validate with

.

Output 2 starts or stops

Output 2 starts or stops

c.

To command output 3, enter one of the user codes in group 3 and validate with

.

Output 3 starts or stops

d.

The personal master code is a super user code to command the outputs. This feature allows you to use
only one code to operate several keypads with the same master code but different user codes. Enter
the personal master code and validate with

and the corresponding output number.

Output 1 activates for 1 second

Output 2 starts or stops

Output 3 starts or stops

e.

The duress code does not need to be programmed. The keypad automatically determines the duress
code by increasing the first digit of user codes in group 1 with two units. All user codes have duress
code function.

Example:

User codes in group 1

Corresponding duress codes

8321

0321

11223

31223

33221

53221

To command the duress function, enter the duress code(s).

Duress output activates (output switches to ground) and output 1
activates for 1 second

Duress output activates (output switches to ground) and output 1
activates for 1 second