7

Door forced-open alarm is disabled

G) Output activation announcer – Installer programming

Locations Code of functions

Validation

Comments

1-second notifying beep is given to notify the person
outside to open the door when the output relay is
activated with a user code or egress button. Good for a
locking device without sound such as a magnetic lock.

Notifying beep disabled and replaced by 2 short
successful code entry beeps for valid user codes

H) User code entry mode (auto or manual) – Installer programming

Locations Code of functions

Validation

Comments

Auto entry code is selected.

key following the user

code is NOT required in code entry. The user code
MUST be set in the same digit length as the master
code in auto entry mode and the code length can be 4
to 8 digits long.

Manual entry mode is selected.

key following the

user code is required in code entry. The user codes
can be 4 to 8 digits long and they are not required to
be the same length as the master code.

NOTE: In single user mode, no matter the selection (auto or manual mode), the master code and the user

code MUST be set as a 4-digit number.

I) Pacifier tones (keypad acknowledgement tones) – Installer programming

Locations Code of functions

Validation

Comments

Pacifier tones available on the keypad

All pacifier tones are off.

J) Allowable time to start door propped-up alarm – Installer programming

Locations Code of functions

Validation

Comments

0

No propped-up alarm

1 to 999

Allowable time from 1 to 999 seconds before door
propped-up alarm starts

K) Exit programming mode

Validation Comments

Exit programming mode and return to normal operation

7. Single User or Multi-User Mode Selection