Dexter Laundry T-30X2 EXPRESS - 60 Hz Gas (On-Premise) User Manual

Page 3

Advertising
background image


3

TABLE OF CONTENTS

DRYER

DIMENSIONS

(Figure

1)

4

UNCRATING

5

INSTALLATION

CLEARANCE

(Figure

2)

6

DRYER EXHAUST SYSTEM (Figure 3)

9

DRYER

SHUTDOWN 10

TOUCH

PAD

LAYOUT

(Figure

4)

11

DRYER

DEFAULT

SETTINGS

12

DRYER

FAULT

CODES

12

TOUCH

PAD

DESCRIPTION 13

OPERATING

INSTRUCTIONS

15

PROGRAMMING

INSTRUCTIONS 17

SERVICING DRYER

23

PREVENTATIVE

MAINTENANCE 23

WARNINGS ABOUT USE AND OPERATION

It is ABSOLUTELY ESSENTIAL that the dryer be grounded to a known earth (zero) ground in
accordance with local codes or, in the absence of local codes, with the latest editions of the
National Electric Code, ANSI//NFPA 70 or Standard CSA C22.1 Canadian Electrical Code Part
1. This is not only for personal safety, but is necessary for proper operation of the controller.
Failure to do so will void the warranty of the controller.

KEEP SHIELDS, GUARDS AND COVERS IN PLACE. These safety devices are provided
to protect everyone from injury.

THIS DRYER IS EQUIPPED WITH A MANUALLY RESETTABLE OVER-
TEMPERATURE THERMOSTAT
located on the end of the burner housing above the gas
valve. Should the dryer cease to operate, refer to your “Service Procedure and Parts Data” book
for instructions.

CHECK THIS THERMOSTAT WHEN INSTALLING DRYER to assure it is not tripped.
Impacts, such as rough handling in shipment, may trip the thermostat. It may be reset by
inserting a wooden (nonconductive) pencil or dowel through the guide bushing in the cover.

NOTE: THIS APPLIANCE SHALL NOT BE USED TO DRY OFF SOLVENTS OR DRY-
CLEANING FLUIDS.

Advertising