Gotham 6 AFW Open Wallwash TRT SpecSheet User Manual

6” afw

Advertising
background image

Luminaire Type:
Catalog Number
(autopopulated):

GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers GA 30012 | P 800.315.4982 | gothamlighting.com

© 2003-2014 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 01/08/14. Specifications subject to change without notice.

PAGE 1 OF 3

AFW-6-OPEN-TRT

Gotham Architectural Downlighting
Compact Fluorescent Downlights

6” AFW

Open Wallwash

Horizontal Lamp
Triple-Tube

FE

AT

U

RE

S

OR

DER

ING

IN

FO

RM

AT

ION

OPTICAL SYSTEM

Self-flanged, semi-specular or matte-diffuse reflector.

Patented Bounding Ray™ Optical Principle design (U.S. Patent No. 5,800,050)
provides lamp before lamp image and smooth transition from top of reflector to
bottom. Minimum flange matches reflector finish.

Highly reflective outer kicker reflector provides smooth, uniform illumination
floor to ceiling, edge to edge. For optimal uniformity, the recommended
luminaire spacing is 3’ from the wall and 3’ centers.

MECHANICAL SYSTEM

16-gauge galvanized steel mounting/plaster frame with integral yoke to retain
optical system. Maximum 1-1/4” ceiling thickness.

16-gauge galvanized steel mounting bars with continuous 4” vertical adjust-
ment are shipped pre-installed. Post-installation adjustment possible without
the use of tools from above or below the ceiling.

Galvanized steel junction box with bottom-hinged access covers and spring
latch. Two combination 1/2”-3/4” and two 1/2” knockouts for straight-through
conduit runs. Capacity: 8 (4 in, 4 out) No. 12 AWG conductors rated for 90°C.

ELECTRICAL SYSTEM

Horizontally mounted, positive-latch thermoplastic socket(s).

Class P, thermally protected, high-power-factor ballast(s) mounted to the
junction box.

SIMPLY5™ technology available.

LISTING

Fixtures are UL Listed for thru-branch wiring, non-IC recessed mounting and
damp locations. Listed and labeled to comply with Canadian standards.

WARRANTY

1-year limited warranty. Complete warranty terms located at

www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx

EXAMPLE: AFW 1/26TRT 6AR MVOLT

Series

Wattage/Lamp

Aperture/Trim color

Finish

Lens type

Voltage

AFW

1/13TRT
1/18TRT
1/26TRT
1/32TRT
1/42TRT

6AR

Clear

6PR

Pewter

6WTR

Wheat

6WR

1

White painted

(blank) Semi-specular
LD

Matte-diffuse

(blank)

No lens

CGL

Clear glass lens

PCL

Clear polycarbonate lens

MVOLT

2

120
277
347

Ballast

3

Options

(blank)

Electronic ballast

ECOS

2, 4

Lutron

®

EcoSystem

®

electronic dimming ballast. Minimum dimming level

5%

ADEZ

4, 5

Advance Mark 10

®

electronic dimming ballast. Minimum dimming level 5%

ADZT

4, 5

Advance Mark 7

®

electronic dimming ballast. Minimum dimming level 5%

WLP

3500 K lamp (shipped separately)

TRW

White painted flange

EL

5, 6

Emergency battery pack with integral test switch

ELR

5, 6

Emergency battery pack with remote test switch

ELHL

5, 6

High-lumen-output emergency battery pack with integral test switch

ELRHL

5, 6

High-lumen-output emergency battery pack with remote test switch

GMF

5

Single, slow-blow fuse

GLR

5

Single, fast-blow fuse

DWW

7

Double wallwash

RRL

8

RELOC

®

-ready luminaire. Provides compatibility with Lithonia RELOC system.

Access above ceiling required.

HW

Hardwire for S5 system; replaces RELOC

®

CP

9

Chicago plenum

BDP

9, 10

Ballast disconnect plug

NEPP

Interface for Sensor Switch

®

nLight

®

network with integral power supply. Refer

to

TN-623-01

.

WRL

11

WL

Wattage restriction label
Wet location; lens required

Advertising