background image

Luminaire Type:
Catalog Number
(autopopulated):

GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers GA 30012 | P 800.315.4982 | gothamlighting.com

© 2007-2013 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 06/06/13. Specifications subject to change without notice.

PAGE 1 OF 3

APR-4-PAR20

Gotham Architectural Downlighting
Incandescent Downlights

4” APR

Open Reflector

PAR20 Lamp 50-Watt Max

OPTICAL SYSTEM

Self-flanged semi-specular, matte-diffuse or specular reflector. Patented Bound-
ing Ray™ Optical Principle design (U.S. Patent No. 5,800,050).

Integrated snoot and optical system minimizes lamp striations normally associ-
ated with PAR lamps and creates visually pleasing scallops on vertical surfaces.

MECHANICAL SYSTEM

16-gauge galvanized steel construction; maximum 1-5/8” ceiling thickness.

Telescopic mounting bars maximum of 32” and minimum of 15”, preinstalled,
4” vertical adjustment.

Toolless post-installation adjustments.

Junction box capacity: 8 (4 in, 4 out) 12AWG rated for 90°C.

ELECTRICAL SYSTEM

Die-cast aluminum lampholder housing.

Medium-base porcelain socket with nickel-plated screw shell.

Thermally activated insulation detector.

LISTING

Fixtures are UL Listed for thru-branch wiring, non-IC recessed mounting and
damp locations. Listed and labeled to comply with Canadian standards.

WARRANTY

1-year limited warranty. Complete warranty terms located at

www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx

EXAMPLE: APR PAR20 4AR

Series

Lamp designation

Aperture/Trim color

Finish

Options

APR

PAR20

PAR20 (50W max.)

4AR

Clear

4BR

1

Black

4PR

Pewter

4WTR

Wheat

4GR

Gold

4WR

1

White painted

(blank) Semi-specular
LD

Matte-diffuse

LS

Specular

SDT

2

277V to 120V stepdown transformer

SDT347

2

347V to 120V stepdown transformer

SF

2

Single fuse

TRW

White painted flange

TRBL

Black painted flange

GSKT

Foam gasketing

RRL

3

RELOC

®

ready luminaire. Provides compatibility with Lithonia

RELOC system. Access above ceiling required.

CP

Chicago plenum

WRL

4

Wattage restriction label

ACCESSORIES order as separate catalog numbers (shipped separately)

SCA4

Sloped ceiling adapter. Degree of slope must be specified (10D, 15D, 20D, 25D, 30D). Ex: SCA4

10D.

FE

AT

U

RE

S

OR

DER

ING

IN

FO

RM

AT

ION

N

OT

ES

ORDERING NOTES

1.

Not available with finishes.

2.

Single fuse standard when SDT or SDT347 options are ordered.

3.

For compatible RELOC systems, refer to

TECH-110

.

4.

Must specify wattage. EX.:WRL35

Advertising