Label description, Specifications – Bray 6P P_P Series User Manual

Page 6

Advertising
background image

Bray Series 6P

Operation and Maintenance Manual

6

Label Description

NOTICE

All Series 6P positioners are supplied as Double Acting.

For Single Acting operation, OUT 2 should be plugged

with a 1/4” NPT plug.

Specifications

Category

Double Acting / Single Acting Pneumatic

Input Signal

3-15 psig (0.2 - 1.0 barg)

Supply
Pressure

20-100 psig (1.4 - 7.0 barg)

Stroke

0 to 90˚

Air
Connection

1/4” NPTF

Gauge
Connection

1/8” NPTF

Protection

IP66

Cam

Linear & Optional Reverse Acting

Ambient
Temperature
Ranges

Std. = -4˚F to +158˚F (-20˚C to +70˚C)
High = -4˚F to +248˚F (-20˚C to +120˚C)
Low = -40˚F to +158˚F (-40˚C to +70˚C)

Linearity

±2.0% Full Scale (F.S.)

Hysteresis

±1.0% Full Scale (F.S.)

Sensitivity

±0.5% Full Scale (F.S.)

Repeatability ±0.5% Full Scale (F.S.)
Air
Consumption

.1 Acfm (1.4 LPM) @ 20 psia (1.4 barA)
.39 Acfm (11 LPM) @ 60 psia (4 barA)

Flow
Capacity

2.8 Acfm (80 LPM) @ 20 psia (1.4 barA)
7.1 Acfm (200 LPM) @ 60 psia (4 barA)

Housing
Material

Die-cast Aluminum, Powder-coated

Weight

3.7 lbs (1.7 kg)

!

Advertising