Component Objects
buttons for page routing, as well as
logic control output nodes indicating
button activity. Logic control output
nodes are always present to verify
CobraNet (CN) and microphone
(MG) signals, and to indicate any
button activity (Any). Networked
Paging Station-1 units are assigned
a Station ID that matches that of
the corresponding block. More than
one unit may be associated with the
same block (Station ID).
Double-clicking the block produces the control dialog. Set Text displays the Station ID on the
block itself. NOTE: The Station ID of a block may be changed in the
Mute
and Level affect audio from the associates microphone(s). Button Name indicates the currently
selected button. NOTE: A Button Name may be changed by right-clicking on the button itself.
Press to Talk
allows selected buttons to be tested, by initiating any assigned Chime signals to
related zone outputs and verifying paging success (via dialog messages and control node
activation). Multiple buttons may be selected for testing by holding down the Shift key. NOTE:
Press to Talk does not activate signal from the microphone itself.
Button routing, priority, and
chime are programmed in the
. Various settings for the Networked Paging
Station-1 units (including Station ID, IP Address, and Lock Code) may be made through software
or during setup of the unit itself (see Networked Paging Station-1 operation
manual).