Copy model number here, Figure 9: ordering specifications 2.0 _description – Brooks Instrument XacTorr CMX160 User Manual

Page 17

Advertising
background image

p.11

2.10 ORDERING SPECIFICATIONS

*Contact Brooks
Technical Support for
other options

Calibration Orientation

H =

Horizontal - Standard
Calibration Orientation

V =

Vertical (for 1 Torr and all
mTorr Ranges)

Reserved for
Brooks Use

C

M

X

4

5

6

7

8

9

10

11

12

Copy Model Number Here

1

2

3

4

5

6

7

8

9

10

11

12

C

M

X

Code

0=
1=
2=
3=
4=
5=
6=
7=
8=
9=

A=
B=
C=

D=

E=
N=
R=

T=

W=

U=
V=

F=

8 UJR (1/2") female
Right angle 8 UJR (1/2") female 30mm +/- 2mm
Short KF16 flange, (A' dimension = 18mm (7.08")

4 VCR (1/4") female
Reserved
KF16 flange with pre-filter assy (A33355-4001)
Wrapped tube with KF16 flange

Short 8 VCR (1/2") male
Reseved
Long 8 VCR (1/2") measues 2-5/8" +1/16"
from base plate to toroid of gland
KF16 - right angle

Short 8 VCR (1/2") female
8 VCR (1/2") female - right angle
2.750" CF
1" additional to tube stub

KF 25 flange
8 VCR (1/2") female
Mini CF
8 VCO (1/2") female (non-standard length)

Fitting Type

0.5" od tube stub (no fitting)
KF 10 flange
KF 16 flange

Code

1 =
2 =
3 =
4 =

5 =

8 =

L =
R =

Note:

1" additional to tube stub

15-Pin w/Fine/Coarse Compatible Zero Switches,
Pin 13 & Pin 14 configured as Inputs for Unique Remote
Zero Functionality. Indy Standard Firmware

1,2 and 3 are available on CMX45 and CMX100.
1, 3, 4 and 5 are available on CMX160

Connector/Interface

9-Pin "D" Male Connector
15-Pin "D" Male Connector with Process relays

15-Pin w/Fine/Coarse Compatible Zero Switches,
Pin 13 & Pin 14 configured as Outputs.
Indy Standard Firmware

DeviceNet w/Analog 9-Pin "D" Female Connector

15-Pin "D" Sub Connector with 2 Process Relays
and a Temperature in Control Relay

15-Pin "D" Sub Connector with 1 Process Relay,
1 Temperature in Control Relay, and an Overheat
Indicator Relay

Range

100 m Torr
250 m Torr
500 m Torr

1 Torr
2 Torr
5 Torr

10 Torr
20 Torr
50 Torr

100 Torr
500 Torr

1000 Torr

1.33 mbar

2 mbar
5 mbar

10 mbar

100 mbar
500 mbar

1000 mbar

13.33 Pa
33.32 Pa
66.65 Pa
133.3 Pa
266.6 Pa
666.6 Pa

1.333 kPa

P11

2.666 kPa

P12

13.33 kPa

P21

66.66 kPa

P25

133.3 kPa

P31

Code

M11
M25
M50

T01
T02
T05
T11
T12
T15
T21
T25
T31

C01
C02
C05
C11
C21
C25

PX1
PX2
PX5

P01

Conversion

100 m Torr

5 Torr

100 m Torr
250 m Torr
500 m Torr

1 Torr

1000 Torr

C31

100 Torr
500 Torr

10 Torr
20 Torr

P02

2 Torr

P05

Operating Temperature

1 = CMX45 (45°C)

2 = CMX100 (100°C)

3 = CMX160 (160°C)

Figure 9: Ordering Specifications

2.0

_DESCRIPTION

Advertising
This manual is related to the following products: