Electrical Connections

1. Electrical Connections

a. Wire yellow homerun control cables to car wash control panel

(See diagram below for wiring schematic)

 Manifold position below designates which port is associated to what color wire.

Example: if you want Presoak 1 to be on manifold port 2, connect the green wire to your

controller relay for Presoak 1.

********************

(HFI supplied motor starter)****************

Electrical Connection

Main Trunk Cable

Wire Color

GROUND

Green/Yellow

DO NOT USE

Blue

Control Voltage Constant

HOT / +

Brown

Neutral / Common

Red

Port 1

White

Port 2

Green

Port 3

Yellow

Port 4

Grey

Port 5

Pink

(Left to right on water manifold, top to bottom on air valves refer to diagram on Page 2)

b. Remove the cap from port 6 then, connect the grey M12

cables hanging out of the motor starter box to the
NEUTRAL/COMMON port 6 of the yellow M12 junction
boxes

i. If you have more panels than grey wires from the

motor starter box, connect the lose grey wires
sent in the shipment into the same jumpers as
the prewired grey cables.

(This step must be completed for unit to function)

c. Connect Powerfast Cordset on motor(s) to motor starter box


d. In the lower left of the enclosure, wire each leg of the incoming power to the terminals

labeled 2T1, 4T2, and 6T3.

Make sure to follow all applicable electrical codes

.