SECTION 9: AIR PUMP SUMMARY

1.

Do not set ARV too high. The ARV is used to control the volume of air needed.

2.

The Air Pump will keep the vent tank topped off with air.

3.

The Air Pump will build air pressure equal to line pressure. It will gradually increase as line pressure increases up

to ARV set point.

4.

If Air Pump is set at 60 lbs. and well is 30-50 lbs., Air Pump psi will start at 30 lbs. and gradually build with line

pressure up to 50 lbs. Air Pump pressure gauge will not register 60 lbs because line pressure does not get that high.

The ARV in this case will act as a pressure relief valve. If psi reaches 60 lbs. the ARV will expel excess air.

SECTION 10: OZONE APPLICATIONS

1.

Consult Ozone manufacturer when using Air Pump for Ozone application.

2.

Ozone voids the Air Pump warranty.