Laurel Electronics LAUREATE SERIES 2 COUNTER-TIMER-SERIAL INPUT METER User Manual

Page 57

Advertising
background image

57

KEYSTROKES FOR SETUP

If the MENU

key does not work, see Section 9 “Enabling & Locking Out Menu Items.”

Press
Menu

Press Digit
Select Key

Press Value Select
Key

0000

Setpoint 1 compared to:

1.

Filtered item

2

Item #2

1

Item #1

3

Item #3

0000

Setpoint 2 compared to:

1.

Filtered item

2

Item #2

1

Item #1

3

Item #3

0000

Setpoint 3 compared to:

1.

Filtered item

2

Item #2

1

Item #1

3

Item #3

SourcE

Source to com-
pare to setpoint

0000

Setpoint 4 compared to:

1.

Filtered item

2

Item #2

1

Item #1

3

Item #3

00000

Relay alarm state when
alarm is active

0

Relay 1 active on

Relay 2 active on

1

Relay 1 active off

Relay 2 active on

2

Relay 1 active on

Relay 2 active off

3

Relay 1 active off

Relay 2 active off

00000

Alarm latching or non-
latching (auto reset)
(see Glossary)

0

AL1 non-latching

AL2 non-latching

1

AL1 latching

AL2 non-latching

2

AL1 non-latching

AL2 latching

3

AL1 latching

AL2 latching

00000

Alarm operates at and
above setpoint (active
high) or at and below
setpoint (active low).
(see Glossary)

0

AL1 active high

AL2 active high

1

AL1 active low

AL2 active high

2

AL1 disabled

AL2 active high

3

AL1 active high

AL2 active low

4

AL1 active low

AL2 active low

5

AL1 disabled

AL2active low

6

AL1 active high

AL2 disabled

7

AL1 active low

AL2 disabled

8

AL1 disabled

AL2 disabled

00000

Hysteresis mode or band
deviation mode
(see Glossary)

0

AL1 band deviation AL2 band deviation

1

AL1 hysteresis

AL2 band deviation

2

AL1 band deviation AL2 hysteresis

3

AL1 hysteresis

AL2 hysteresis

4

No deviation or hysteresis on menu

5

AL1 span hysteresis AL2 band deviation

6

AL1 span hysteresis AL2 hysteresis

7

AL1 span hysteresis AL2 span hysteresis

AL SEt

Alarm Setup
for relays 1 & 2
if detected.

Press

until

ALSEt is
displayed.

00000

Number of consecutive
readings in alarm zone to
cause an alarm

0

After 1 reading

4

After 16 readings

1

After 2 readings

5

After 32 readings

2

After 4 readings

6

After 64 readings

3

After 8 readings

7

After 128 readings